Free tool for offshore and commercial marine
Log the gauge readings you already take on your rounds. Get a plain answer on what your seawater RO is doing and what to check next.
Works with any make or model of seawater RO watermaker. Not tied to any manufacturer, including H2O's own Blue Cube units.
Fouling
Production down 25 percent, pressure drop up 80 percent, all corrected.
Potable water makers on production platforms, drilling rigs, and FPSOs.
OSVs, tugs, crew boats, research and survey vessels, and other working vessels.
One high pressure pump feeding one line of up to eight 4 or 8 inch seawater membranes, open intake, single pass. Any make, any model, any membrane brand.
Six quick questions, once.
Pressures, flows, TDS, temperature. Skip anything you do not have.
Readings are corrected for water temperature and pressure and compared with the day your unit was healthy, then you get a green, yellow, or red result with one clear next step.
Every limit in this tool comes from published membrane manufacturer data: the DuPont FilmTec Technical Manual and element data sheets, with Nitto Hydranautics specifications noted where they differ. Drinking water checks cite US EPA, WHO, and the US Public Health Service Vessel Sanitation Program. The method follows ASTM D4516 for normalizing RO data. Nothing is an in-house guess.
Three published sources sit behind the limits this tool checks. The DuPont FilmTec Technical Manual (Form 45-D01504-en, Rev. 20, Tables 22 and 23) gives the average flux range for 8 inch seawater elements and the 13 percent maximum recovery per element. Table 23 of the same manual gives the equivalent range for 4 inch elements. The FilmTec seawater element product data sheets give the hard limits: a maximum operating pressure of 1,200 psig (83 bar), a maximum operating temperature of 113 degF (45 degC), a maximum pressure drop of 15 psig (1.0 bar) per element, a maximum feed SDI of 5, a free chlorine tolerance below 0.1 ppm, and a continuous pH range of 2 to 11. Maximum temperature for continuous operation above pH 10 is 95 degF (35 degC), so alkaline cleaning solutions must not be heated past that. Hydranautics and Toray publish equivalent limits for their seawater elements; this tool uses the DuPont figures because they are the most widely referenced, and a user can override active area and nominal rejection in setup. On recovery, the 25 to 40 percent overall band shown on the card is common industry practice for single pass seawater rather than a manufacturer limit, while the 13 percent per element figure is DuPont's published maximum and is what turns the recovery bar red. On temperature, manufacturers publish no minimum. Water flux drops roughly 3 percent per degC below 25 degC, so cold feed needs more pressure for the same output. The practical floor is the point where the pressure needed reaches the 83 bar data sheet maximum. This tool corrects for temperature using the same relationship, so a cold reading is compared fairly against your baseline. Flow limits come from the DuPont FilmTec Reverse Osmosis/Nanofiltration Membranes Technical Manual (Form 45-D01504-en, Rev. 20, August 2026). For seawater with conventional pretreatment and a feed SDI under 5, Table 22 gives 62 gpm (14 m³/h) maximum feed and 15 gpm (3.4 m³/h) minimum concentrate for 400 ft² 8 inch elements, and Table 23 gives 16 gpm (3.6 m³/h) maximum feed and 4 gpm (0.9 m³/h) minimum concentrate for 4 inch elements. The tool applies the 8 inch figures to every 8 inch element, including 440 ft² models. DuPont allows higher feed and lower concentrate flows with membrane pretreatment, and Nitto Hydranautics publishes 85 gpm maximum feed and 12 gpm minimum concentrate for its SWC5-LD and SWC6-LD elements and 16 gpm and 3 gpm for SWC5-LD-4040 on the individual element specification sheets. This tool uses the stricter conventional pretreatment figures for every element so the check is consistent on an open intake.
H2O recommends a continuous operating range of 6.5–12.99 gallons per square foot per day (GFD), equivalent to 11.0–22.1 LMH. Below 6.5 GFD (11.0 LMH) is red: under production. From 6.5 through 13 GFD (22.1 LMH) is green: membranes should foul at typical rates. Above 13 and below 14 GFD is yellow: membranes should foul at an increased rate. At 14 GFD (23.8 LMH) or higher is red: membranes should foul at a rapid rate. These H2O guidelines apply to both 4 inch and 8 inch elements and are not model-specific manufacturer limits. Flux is hourly product flow divided by total active membrane area. The setup page calculates flux at rated capacity; readings and results show rated or measured flux outside the green range. Total available active membrane area is element count times active area per element, shown in square meters and square feet. The recommended production range is calculated from that area at 6.5 and 12.99 GFD and shown in cubic meters per day and gallons per day. Unknown membrane areas are labeled estimated.
The 500 mg/L TDS figure and the 6.5 to 8.5 pH range are the US EPA National Secondary Drinking Water Regulations at 40 CFR 143.3. They are set for taste, smell and appearance rather than health, and they are the numbers most watermaker divert valves are set against. The roughly 1,000 mg/L point comes from the WHO Guidelines for Drinking-water Quality, which treat water above about that level as increasingly unpalatable. For vessels, the WHO Guide to Ship Sanitation and the Maritime Labour Convention 2006 both point back to the WHO drinking water guidelines rather than setting separate numbers, so the same figures apply at sea. For the potable tank, the disinfectant numbers come from three places: the US EPA maximum residual disinfectant level for chlorine of 4.0 mg/L at 40 CFR 141.65; the WHO Guidelines for Drinking-water Quality, which ask for at least 0.2 mg/L free chlorine at the point of delivery and give 5 mg/L as a guideline value; and the US Public Health Service Vessel Sanitation Program Operations Manual, which sets a minimum of 0.2 mg/L and a maximum of 5.0 mg/L free residual halogen and allows bromine as well as chlorine. The 0.5 to 1.0 mg/L band this tool calls normal is an operating target used on vessels and platforms so the residual survives the whole system; it is not a regulatory number. Disinfectant is dosed into the product water after the membranes. Chlorine must never reach the feed side, because it destroys polyamide membranes; that is a different issue and is covered by the mechanical or oxidant damage verdict.
Product flow is corrected for feed temperature with the standard temperature correction factor TCF = exp(3000 x (1 / (273 + T) - 1 / 298)) and for driving pressure with the ratio of baseline net driving pressure to this reading's net driving pressure, so Qp_n = Qp x TCF x (NDP_b / NDP). Salt passage is the product salinity divided by the average feed-concentrate salinity, SP = Cp / Cfc, and is corrected as SP_n = SP x (Qp / Qp_b) x (TCF / TCF_b). Because SP is already measured against the average feed-concentrate salinity, no further feed salinity term is applied; adding one would count the feed twice, and a unit moved to saltier water would look as though its membranes had improved. Vessel pressure drop is corrected for flow as dP_n = dP x ((Qf_b + Qc_b) / (Qf + Qc))^1.5, and for viscosity. Pressure drop is also corrected for water viscosity, which rises about 2.4 percent per degree C below 25 C. Some manufacturer normalization programs omit this; it is included here so a cold reading does not look like fouling.
Most often it is cold feed water, not a fault: output falls about 3 percent for every degree C the sea cools. If output is down after correcting for temperature and pressure, the cause is usually fouling, scaling, dirty prefilters, or aging membranes, and each leaves a different pattern in the gauge readings.
The usual causes are feed pressure set too low, a failing salinity probe, a leaking o-ring or seal, or membranes damaged by chlorine. A handheld TDS meter tells a bad probe from a real problem in a minute.
DuPont's guidance is to clean when corrected product flow drops 10 to 15 percent, corrected salt passage rises noticeably, or pressure drop across the vessels rises 15 percent. Correcting for temperature matters, or you will clean every winter for nothing.
When the pressure drop across them rises by about 10 psi over a clean set, rather than on a fixed calendar. Filter life that keeps getting shorter points to a change in the intake water.
RO removes the minerals that give water taste and lets carbon dioxide pass through, so the product is slightly acidic. A remineralizing post-filter or pH adjustment fixes the taste and protects copper and brass piping.
Enough to overcome the osmotic pressure of the seawater with margin, typically 55 to 70 bar (800 to 1,000 psi) on a single pass unit, and never above the 83 bar (1,200 psi) maximum on the membrane data sheet.
At least 0.2 mg/L free chlorine at the tap, per WHO and the Vessel Sanitation Program, with 0.5 to 1.0 mg/L a common operating target and 4.0 mg/L the US EPA maximum.
The method behind this tool, written for chief engineers and rig maintenance supervisors.
Published by H2O Inc.
The limits and thresholds here are set for commercial seawater units, and on other systems the results would mislead you. For a land-based plant, your membrane manufacturer's design software is the right tool. For a small-boat watermaker, your watermaker manufacturer is the best source of help.
Free to use with any brand of watermaker. No account needed to check a reading. Save your log when you want trends.